SETTING TIME TEST FOR CEMENT

SETTING TIME

OBJECTIVE
To determine the initial & final setting time of cement.

APPARATUS
MEASURING INSTRUMENTS
NAME
CAPACITY / RANGE / SIZE
ACCURACY / LEAST COUNT
Vicat apparatus
Should be made as per IS:5513
 —
Balance
1000 g
1 g
Measuring cylinder
100 ml
1 ml
Stop watch
30 min.
0.2 sec

OTHER APPARATUS
Glass plate, enamel tray, trowel
             

                                                  Fig:-Showing Vicat Apparatus

ENVIRONMENTAL CONDITION
Temperature
27 ± 2C
Relative Humidity
90 % (min)

PROCEDURE
(A) TEST BLOCK PREPARATION
1.      Before commencing setting time test, do the consistency test to obtain the water required to give the paste normal consistency (P).
2.      Take 400 g of cement and prepare a neat cement paste with 0.85P of water by weight of cement.
3.      Gauge time is kept between 3 to 5 minutes. Start the stop watch at the instant when the water is added to the cement. Record this time (t1).
4.      Fill the Vicat mould , resting on a glass plate, with the cement paste gauged as above. Fill the mould completely and smooth off the surface of the paste making it level with the top of the mould. The cement block thus prepared is called test block.
(B) INITIAL SETTING TIME
1.      Place the test block confined in the mould and resting on the non-porous plate, under the rod bearing the needle.
2.      Lower the needle gently until it comes in contact with the surface of test block and quick release, allowing it to penetrate into the test block.
3.      In the beginning the needle completely pierces the test block. Repeat this procedure i.e. quickly releasing the needle after every 2 minutes till the needle fails to pierce the block for about 5 mm measured from the bottom of the mould. Note this time (t2).
(C) FINAL SETTING TIME
1.      For determining the final setting time, replace the needle of the Vicat’s apparatus by the needle with an annular attachment.
2.      The cement is considered finally set when upon applying the final setting needle gently to the surface of the test block; the needle makes an impression thereon, while the attachment fails to do so. Record this time (t3).
CALCULATION
Initial setting time=    minutes
Final setting time=      minutes
Where,
t1=Time at which water is first added to cement
t2=Time when needle fails to penetrate 5 mm to 7 mm from bottom of the mould
t3=Time when the needle makes an impression but the attachment fails to do so.
PRECAUTIONS
§  Release the initial and final setting time needles gently.
§  The experiment should be performed away from vibration and other disturbances.
§  Needle should be cleaned every time it is used.
§  Position of the mould should be shifted slightly after each penetration to avoid penetration at the same place.
§  Test should be performed at the specified environmental conditions.