SETTING
TIME
OBJECTIVE
To determine the initial & final setting time of
cement.
APPARATUS
MEASURING INSTRUMENTS
NAME
|
CAPACITY / RANGE / SIZE
|
ACCURACY / LEAST COUNT
|
Vicat apparatus
|
Should be made as per IS:5513
|
—
|
Balance
|
1000 g
|
1 g
|
Measuring cylinder
|
100 ml
|
1 ml
|
Stop watch
|
30 min.
|
0.2 sec
|
OTHER APPARATUS
Glass plate, enamel tray, trowel
|
Fig:-Showing Vicat Apparatus
ENVIRONMENTAL CONDITION
Temperature
|
27 ± 20 C
|
Relative Humidity
|
90 % (min)
|
PROCEDURE
(A) TEST BLOCK PREPARATION
1.
Before commencing setting time test,
do the consistency test to obtain the water required to give the paste normal
consistency (P).
2.
Take 400 g of cement and prepare a
neat cement paste with 0.85P of water by weight of cement.
3.
Gauge time is kept between 3 to 5
minutes. Start the stop watch at the instant when the water is added to the
cement. Record this time (t1).
4.
Fill the Vicat mould , resting on a
glass plate, with the cement paste gauged as above. Fill the mould completely
and smooth off the surface of the paste making it level with the top of the
mould. The cement block thus prepared is called test block.
(B) INITIAL SETTING TIME
1.
Place the test block confined in the
mould and resting on the non-porous plate, under the rod bearing the needle.
2.
Lower the needle gently until it
comes in contact with the surface of test block and quick release, allowing it
to penetrate into the test block.
3.
In the beginning the needle
completely pierces the test block. Repeat this procedure i.e. quickly releasing
the needle after every 2 minutes till the needle fails to pierce the block for
about 5 mm measured from the bottom of the mould. Note this time (t2).
(C) FINAL SETTING TIME
1.
For determining the final setting
time, replace the needle of the Vicat’s apparatus by the needle with an annular
attachment.
2.
The cement is considered finally set
when upon applying the final setting needle gently to the surface of the test
block; the needle makes an impression thereon, while the attachment fails to do
so. Record this time (t3).
CALCULATION
Initial setting time= minutes
Final setting time= minutes
Where,
t1=Time at which water is
first added to cement
t2=Time when needle fails
to penetrate 5 mm to 7 mm from bottom of the mould
t3=Time when the needle
makes an impression but the attachment fails to do so.
PRECAUTIONS
§ Release the initial and final setting time needles gently.
§ The experiment should be performed away from vibration and
other disturbances.
§ Needle should be cleaned every time it is used.
§ Position of the mould should be shifted slightly after each
penetration to avoid penetration at the same place.
§ Test should be performed at the specified environmental
conditions.
No comments:
Post a Comment